Dear Experts,
There is a problem in the configurations between QA ECC and PI systems.So that no data is flowing from QA ECC to PI.
In general if we run a program in ECC then automatically the data flows to pi and we can monitor in SXMB_MONI in ECC side.But now the
T_CODE is not triggering and no data is flowing.
After running SLDCHECK in ECC QA, the below error of n busines systems not maintained has occured but the business systems are mentioned in PI QA.
Exchange Infrastructure: Test LCR Connection
Properties of RFC destination SAPSLDAPI
RFC host:
%%RFCSERVER%%
program id: SAPSLDAPI_GPQ
gateway host:
spiqa
gateway service: sapgw00
Testing the RFC connection to the SLD java client...
RFC ping was successful
SLD server access settings:
host name: 10.250.4.173
port number: 50000
user : slddsuser
Use transaction SLDAPICUST if you wish to maintain the SLD server access data
Launching the SLD GUI in a separate browser window...
=> Verify in the browser GUI that the SLD is in a healthy running state!
Calling function LCR_LIST_BUSINESS_SYSTEMS
Retrieving data from the SLD server...
Function call terminated sucessfully
No business systems maintained in the SLD
=> Check data integrity within the SLD!
Summary: Connection to SLD works technically, but the SLD content may need maintenance
=> Check and maintain the SLD data content
Thanks,
Hylinda